Loudspeakers Line Isolator System

Technical Specifications
Electrical Mains power supply
Voltage 115 / 230 VAC, ±10%, 50/60 Hz
Fuse rating T6.3 A, 250 V
Inrush current Time: < 10 ms; ≤ 30 A
Max. power consumption 150 W
Battery power supply
Voltage 18 – 56 VDC nominal 24 or 48 VDC
Backup fault detection level 21 ± 1 VDC
Max. backup power current 4.5 A
Hardware Interfaces
100 V audio I/O (loop 1‑6) Pluggable screw connector
Fault output (loop 1‑6) Floating contacts 24 V, 1 A
Fault relays except general fault
relay
• OK state is normally deenergized
• NO is open
General fault relay • OK state is Failsafe, normally energized
• NC is open (failsafe)
Performance
Max. number of Isolator Boards
in loop
50
Power handling capacity per loop 500 W
Frequency range 50 Hz – 20 kHz
Mechanical Dimensions (H x W x D)
For 19” rack use, with brackets 88 x 483 x 400 mm (3.5 x 19 x 15.7 in)
 in front of brackets 40 mm (1.6 in)
behind brackets 360 mm (14.2 in)
Weight 15.9 kg (35.05 lb)
Mounting 19” rack
Color Charcoal with silver
Environmental Operating temperature -5 ºC to +55 ºC (+23 ºF to +131 ºF)
Storage temperature -20 °C to +70 ° C (-4 °F to +158 °F)
Relative humidity 15% to 90%
Air pressure 600 to 1100 hPa

دریافت دیتاشیت