PVA-CSK Call station kit

دریافت دیتاشیت

Technical Specifications
Buttons (through screw-terminal
connectors)
5 pre-programmed 15 programmable
zone/function buttons 3 supervised
programmable optional emergency
buttons 2 connections for each button;
23 buttons share 6 common VCCs (3V3 - DC)
Each button has short circuit protection
LEDs connected to buttons
(through screw-terminal connectors
This kit supports open drain outputs with
max. 5 mA per output. Using the internal
supply, a maximum of 100 mA can be
sourced for all outputs. The kit also provides
an external power supply for lighting LEDs of
external normal buttons. 2 connections
(VCC & open collector) are available for
each LED connected to a button. In total,
38 LEDs share 10 common MIX_PWR_LED.
These LEDs are supplied with 5 V DC using
the internal power supply. The connected LEDs
are supplied with 24 V DC using the
external power supply. Each LED circuit has
short-circuit protection.
Power LED (through screwterminal
connectors)
Driven by MIX_PWR_LED (5 V DC or 24 V DC)
2 connections (VCC & open collector)
Fault LED (through screwterminal
connectors)
Driven by MIX_PWR_LED (5 V DC or 24 V DC)
2 connections (VCC & open collector)
Alarm LED (through screwterminal
connectors)
Driven by MIX_PWR_LED (5 V DC or 24 V DC)
2 connections (VCC & open collector)
Included LCD display kit A flat ribbon cable connects the
display to the call station kit
mainboard. The ribbon cable
length is +/- 300 mm
Others (through screw-terminal
connectors)
1 audio source (line in) 1 supervised
microphone input (LBB9081) capsule and
PTT button connection (input & VCC)
with short-circuit protection.
1 loudspeaker connection,
1 additional +24 V DC power supply
External connectors 1 call station bus connector
(control data + audio + power supply, RJ-45)
1 EXT connector (RJ-12, e.g. for
call station extension)
Main power supply
• Nominal voltage 24 V DC (-10%/+30%)
• Maximum voltage range 15–58 V DC
Nominal current consumption
for main power supply
< 100 mA
Maximum supply current
• External power supply for lighting,
without extensions
< 80 mA/24 V
< 110 mA/18 V
• Internal power supply for lighting,
without extensions
< 150 mA/24 V
< 200 mA/18 V
CAN interface 10, 20, or 62.5 kbit/s
Maximum mic input level -21 dBu
Maximum line input level +4 dBu
NF output Balanced
• Nominal level +6 dBu
• Maximum level +12 dBu
Frequency response 200–16,000 Hz, +0/-3 dB
Signal-to-noise ratio
(Mic and Line input, NF output)
≥ 60 dB
Buttons
• Nominal voltage 3.3 V DC
• Max current 100 mA
PTT input switch
• Nominal voltage 3.3 V DC
• Max current 100 mA
LEDs
• Nominal drive current 5 mA for each LED
• Maximum drive current 20 mA for each LED
• Nominal drive voltage • 5 V by internal power supply for 5-V
point lighting LEDs
• 24 V by external power supply for
24-V ring lighting LEDs
Additional power supply for industrial buttons backlight
• Nominal voltage 24 V DC (-10/+30%)
• Nominal current consumption < 300 mA
• Maximum supply current t < 500 mA at 24 V
External speaker
• Nominal resistance 8 Ω
• Power rating 1.5 W
• Maximum power 2 W
• Nominal operating voltage  3.5 V
Normal microphone (LBB9081 reference)
• Sensitivity 3.1 mV/Pa ±4 dB
• Frequency response 280–14000 Hz
• Rated output impedance 500 Ω
• Polar pattern Omnidirectional
• Switch On/off with remote control contact