PVA-4CR12 Controller

Technical Specifications
Audio 8 audio inputs, 4 audio outputs
Safety/redundancy Internal supervision, system monitoring,
watchdog, fault output
PC configuration and control software • Configuration Wizard: Easy system configuration.
 • IRIS-Net: Integration of controller, amplifiers, call stations, routers and peripheral control; configuration, control, and supervision for complete audio systems; programmable user control panels and access levels.
• Hot Swapper (included in IRIS-Net package): Easy updating of messages during runtime.
Frequency response (ref. 1 kHz) 20 Hz to 20 kHz (-0.5 dB)
Signal-to-noise ratio (A-weighted) Line in to line out: 106 dB typical
THD+N < 0.05%
Crosstalk (line level) Line in to line out (0 dB gain): < 100 dB at 1 kHz
Sample rate 48 kHz
DSP processing resolution 24-bit linear A/D and D/A conversion,
48-bit processing
Audio inputs (microphone/line level) MIC/LINE: 2 ✕ 3-pin port, electronically
symmetric AUX: 2 ✕ Stereo RCA
• Input level (nominal) MIC/LINE: 15 dBu
AUX: 9 dBu
• Input level (max. before clip) MIC/LINE: 18 dBu AUX: 12 dBu
• Input impedances MIC/LINE: 2.2 kΩ
AUX: 8 kΩ
• Common mode rejection MIC/LINE: > 50 dB
• Phantom power, switchable MIC/LINE: 48 V DC
• A/D conversion 24 Bit, Sigma-Delta, 128 times oversampling
Audio inputs (100 V) AMP IN: 2 ✕ 6-pin port
• Max. voltage 120 V
• Max. current 7.2 A
• Max. power 500 W
Audio outputs (line level) LINE OUT: 1 x RJ-45, 4 x 3-pin port
• Output level (nominal)  6 dBu
• Output level (max. before clip) 9 dBu
• Output impedance < 50 Ω
• Min. load impedance 400 Ω
• D/A conversion 24 Bit, Sigma-Delta, 128 times oversampling
Audio outputs (100 V) SPEAKER OUT: 2 ✕ 12-pin port
• Max. voltage 120 Veff
• Max. current 7.2 A
• Max. power 500 W
• Crosstalk (100 V) AMP IN to SPEAKER OUT:
 < 100 dB at 1 kHz with 1 kΩ load
Call station bus (CST) 4 ✕ integrated power+CAN
+audio interface, RJ-45
• Power +24 V DC, electronic fuse
• CAN 10, 20 or 62.5 kbit/s
• Audio electronically symmetric
• Max. length 1000 m
ANALOG CONTROL IN 1 ✕ 12-pin port
• Control inputs • 8 (analog 0-10 V/logic control; low:
U ≤ 5 V DC; high: U ≥ 10 V DC; Umax = 32 V DC)
• Reference outputs • +10 V, 100 mA
• GND
• Time sync input 1 (DCF-77 receiver)
CONTROL OUT HP 1 ✕ 12-pin port
• Control outputs • 6 High Power outputs
(open collector, Umax = 32 V, Imax = 1 A)
• Reference output V • +24 V, Imax = 200 mA
• Ready/fault output 1 (NO/NC relay contacts,
Umax = 32 V, Imax= 1 A)
• Slave clock output 1 (24 V DC, max. 1 A)
CONTROL IN 2 ✕ 10-pin port
• Control inputs • 5 supervised inputs (0– 24 V, Umax = 32 V)
• 5 isolated inputs (low: U ≤ 5 V DC;
high: U ≥ 10 V DC; Umax = 32 V)
CONTROL OUT 2 ✕ 10-pin port
• Control outputs 12 Low Power outputs (open collector,
Umax = 32 V, Imax = 40 mA)
• Control relay 1 (NO/NC relay contacts, Umax = 32 V, Imax= 1 A)
Interfaces
• Ethernet 1 ✕ RJ-45, 10/100 MB (for PC connection)
• CAN BUS port 2 ✕ RJ-45, 10 to 500 kbit/s
(for amplifier, router connection
• OM-1 interface Module (optional) Ethernet connectors (Primary / Secondary)
100/1000 Mbit/s, RJ-45,
integrated transformer isolation
DC power input 21–32 V DC
Power consumption 10 to 250 W
Operating temperature -5 °C to +45 °C (+23 °F to +113 °F)
Storage and transport temperature -40 °C to +70 °C (-40 °F to +158 °F)
Electromagnetic environment E1, E2, E3
Product dimensions
(Width ✕ Height ✕ Depth)
19”, 2 HU, 483 x 88.2 x 391 mm
Net weight 8.0 kg
Shipping weight 9.5 kg

دریافت دیتاشیت